Technical dataTest space volumes 190, 335, 600, 990 and 1540 l
Performance range
for temp. tests| Temperature range | -42(-45)°C to+180°C | | -72(-75)°C to+180°C | | Temp.change rate | | | Cooling | 2,3 to 4,0 K/min | Heating
| 3,0 to 4,0 K/min | | Heat compensation | 1500 to 4500 W max. |
Performance range
for climatic tests| Temperature range | +10 °C to +95 °C | | Dew point temp. | +4 (-3°C*) to +94°C | | Humidity range | 10 to 98 % RH | | Heat compensation | 400 to 500 W max. |
*) discontinuous operation | | |
|